Showing results: 91 - 105 of 161 items found.
-
8001 -
April Instrument
4 digit BCD, 1 latch control line, 25 pin female, D type connector. Range: 2 to 8 GHz (1.7 - 9.0 GHz, typical). 3 normal switching mode, SSB phase noise will be degraded in the fast switching mode
-
TG23P -
Aircraft Development Industries cc
The model TG23P is an entirely solid state digital 3 Phase, 2 pole, Tachometer Generator Simulator. There are no motors, strobe lights or moving parts in the unit which makes it ideal for testing electro-mechanical type Tachometers, Percent RPM Indicators, Dual and Triple Tachometer indicators
-
MR-1A -
TEGAM Inc.
# No need to disconnect drive shaft couplings# Identifies open windings# Protects user and equipment# Reliable, solid state components# Shirt pocket size, 48" leads with heavy duty 1/2" clips, works on most sizes and types of 3 phase motors
-
597C -
Red Phase Instruments Australia Pty Ltd.
The Model 470A has similar software and performance as the Model 465C. It is packaged in a 19? style bench-top case with all connections on the front panel for use in meter test benches. It has inputs for comparison with another polyphase standard or 3 separate single phase standards for verifying calibration accuracy.
-
XY Plotter -
ZETLAB Company
XY Plotter is used for visualizing (form evaluation) the transfer characteristics of two values to be measured. The following instruments can be used for transfer characteristics: DC and AC voltmeters, a selective AC voltmeter, a frequency meter, and a phase meter. Characteristics can be displayed in 3 planes (XY, XT, and YT), as well as in a three-dimensional (XYT) view.
-
1810 EL -
Standard Electric Works Co., Ltd
● Taut Band movement.● Simple operation.● Wiring check.● Robust.● Can be used on 2 wires L-E (ELCB/RCCB/GFCI tester).● Can be used on 3 wires L-E-N (with wiring check).● No battery required.● Sense automatically 50 or 60 Hz.● Current injected in phase with the voltage.● Other voltage optional (110V).
-
61700 -
Chroma Systems Solutions, Inc.
Power: 1500VA, 3 (61701); 3000VA, 3 (61702); 4500VA, 3 (61703); 6000VA, 3 (61704); 12000VA, 3 (61705)Voltage: 0~150V/0~300VFrequency: 15~1.2KHzPhase angle: 0~360Built-in PFC, provides input power factor over 0.98Advanced PWM technology delivers high power density in a compact rack-mountable packageBuilt-in output isolation relaysAC+DC output modeProgrammable slew rate setting for changing voltage (optional function)Turn on, turn off phase angle controlUser-definable power-on statusPower line disturbance (PLD) simulation capability (optional function)Comprehensive measurement capability: V, Irms, Ipk, I inrush, P, PF, CF of current etc.Programmable r.m.s. current limitFull protection: OP, OC, OV and OT protectionGPIB and RS-232C interface (optional)Easy-use software for operation
-
ETEK TECHNOLOGY CO., LTD
1. Design and implementation of RF front end receiver module. 2. Design and implementation of RF front end transmitter module. 3. Design and implementation of voltage controlled oscillator and phase lock loop. 4. Design and implementation of IF demodulator and audio process circuit. 5. Design and implementation of wireless transceiver module.
-
Weshine Electric Manufacturing Co., Ltd
The instrument can measure single capacitor of single phase or three-phase shunt capacitor bank without removing wires.2. The instrument has the functions of inductance, resistance and current measurement.3. The instrument has two power supply modes: External AC220 V and built-in lithium battery meet various application scenarios.
-
Howard Butler Ltd.
The new range of Hobut multifunction panel meters feature 96 x 96mm sizes complete with unique blue LED screen, which can be seen in direct sunlight. The range is easy to use, features user-programmable CT & VT ratios, and can be used on any single or 3 phase system with any input voltage without re-programming.
-
OEwaves, Inc
OEwaves’ HI-Q® Optical Test Measurement System utilizes a homodyne methodology for automated measurement capable of testing ultra-low phase noise laser sources. The user friendly test system is capable of rapidly measuring laser phase noise and estimating its FWHM linewidth down to < 3 Hz without complex setup or reference lasers normally required to make such a narrow linewidth measurement.
-
1813 EL -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● 2 Lines × 16 characters LCD.● Very low consumption.● Suitable for domestic version.● Better than 3% accuracy (current).● Menu-driven.● Accurate digital readout of disconnection time.● Accurate digital readout of disconnection sensitivity.● Automatic data hold function.● Zero crossing circuitry permit testing at 0° or 180°.● Disconnection phase polarity shown on LCD display.● Auto off and off override.● Polarity trip indicator (positive or negative phase)● Wiring polarity indicator.● Measure voltage between Line and Earth before testing.● 60Hz available.
-
426E01 -
PCB Piezotronics, Inc.
Nominal Microphone Diameter: 1/2 Gain -0.05 dBFrequency Response (0.1 dB) (re 1 kHz)6.3 to 125000 HzFrequency Response (-3 dB) (re1 kHz) Phase Linearity (<1 )32 to 20000 Electrical Noise (A-weight)<2.8 V<2.8 V[1] Output Slew Rate 2 V/S[2]
-
TPS3000 -
TDK-Lambda Corp.
The TPS3000 industrial AC-DC power supplies offer output power up to 3.2kW in a 2U high package with 3 phase supply input.Features include voltage and current programming, remote on/off, remote sense, a standby supply, PMBus communication, built in ORing FET and wide operating temparature range of -40°C to +70°C
-
Aero Nav Laboratories, Inc.
HALT consists of high and low temperature and 3 axis vibration testing performed either individually or in combination.Highly accelerated life testing is performed to identify design weaknesses and problems prior to production. HALT subjects equipment to overstress conditions at a level which does affect life, but offers an advantage by reducing the design and development phases of a program.